SmartCon system: Containment made easy
Easy big bag emptying up to OEB 4 - with the new SmartCon system 1. In order to maintain the leakproofness of the system, the liner residue of the previously emptied big bag should only be removed when a new big bag has been connected., 2. The pressure lid must be lifted and the separated outlet must be manually placed in the emptying hopper. , 3. In order to connect a new big bag to be emptied, the big bag outlet must simply be placed over the emptying unit. , 4. The pressure plate moves down automatically. Pneumatic seals fasten the big bag outlet securely into place on the docking system., 5. Now, the cover of the engagement connection can be opened without tools., 6. The operator can use the engagement connection with an endless liner system to safely reach for the separated liner., 7. The separated liner is removed from the engagement connection., 8. The piece of foil and the liner contained within it can now be untied, separated and disposed of., 9. After the engagement connection cover has been closed, the contamination-free emptying can begin., 10. After the emptying process has finished, the big bag outlet can be untied and separated with the docking system. The process then starts again from the beginning., The optional leakproofness test can detect even the smallest amounts of damage to the foil liner outlet., The operating personnel are guided through the process by a control system that specifies all the work steps.