Neuer ACO Blog
Supplier sign in
Home
Suppliers
News
Jobs
Events
Articles
STAY INFORMED
Subscribe to our monthly newsletter.
Your email address will never be disclosed to any third party.
Read our
privacy notice.
Product news
29-05-2017 |
20873 x
Share:
More information
ACO Blog
New ACO Blog
Read all about moisture measurements and moisture analyzer
Visit our new ACO blog! Read all about online moisture measurements, hand held moisture devices and laboratory devices. https://www.acoweb.de/en/blog
Company information
ACO Automation Components; Moisture Measurement, Feuchtemessung
ACO Automation Components; The experts for moisture measuring Measurement, Display, Command, Control Products and solutions from ACO: - online moisture measurement systems directly in process - laboratory moisture measurement devices - humidity in air or gases (r.H.) up to 300°C and in ppm-range - Eex-sensors - monitoring and controlling moisture values We won’t leave you on your own: Through our long-term experience in moisture measurements ACO can offer you an individual and cost-effectively solution for your measurement conditions. Application area of ACO moisture measurement systems: - concrete industry - ceramic industry - wood-processing industry (wood chips, sawdust) - grain industry - chemical industry - clay industry - feed industry - food industry On our website you will find a detailed list of pre-measured materials from ACO. Obviously ACO is testing new material in-house laboratory on request.
Last update: 16-10-2025
More items
ACO moisture sensor in SFM4 bypass screw
ACO moisture measurement for biomass like wood chips, sawdust and wood shavings
Properties: Ideal material conditions for the on-line moisture measurement Flexible mounting of the bypass screw conveyor Maintenance flap for taking samples Subsequently applicable Great experience in the field of saw dust Versions: Length, height, dimensions of flanges on customer requirements Version for explosion-risk areas (EX) The SFM4 bypass screw compaction unit has to be placed in a free fall situation of material, e.g. in a drop shaft. A partial flow of this material is trapped in the first section of the compaction unit. The screw compactor compresses the material and conveys it into the second part of the unit, right across the installed ACO moisture sensor for the determination of the residual moisture. Then the material falls down through a drop pipe back into the process. Based on this constant and equal conditions (density, dumping height, etc...) precise measuring results are available.
07-03-2017 |
25898
| product news |
Continue reading
Hygienic application for ACO moisture measuring systems
ACO moisture measuring instruments: food industry and pharma industry
ACO-Automation Components shows a hygienic solution for using their moisture measurement systems in the food and pharma industry. An ACO moisture measuring sensor determines the water content/residual moisture of bulk material through a food approval plastic plate. This installation kit has been specially developed for measuring bulk goods in screw conveyors. This method prevents a direct contact between the moisture measurement sensor and the bulk solids. https://www.acoweb.de/en/produkte
30-09-2016 |
24888
| product news |
Continue reading
Feuchtemessung - ein Muss in der Holzindustrie
increasing quality – increasing efficiency – saving money
The field of application for wood is extremely varied. Using wood as a renewable energy source is one of the fastest growing application area for wood. In this kind of timber industry wood is processed in quiet different ways. A few examples for usable material- or transport forms are wood-chips, wood-pellets, wood-shavings or sawdust. To reach a highly effective combustion in the wood-burning ovens a moisture measurement is absolutely essential. On one hand a moisture measurement is able to measure the exact residual moisture in the material. The quality of all produced wooden bulk-materials increases highly by using a moisture measurement. And on the other hand there is also the possibility to raise the efficiency of a plant through optimizing cost-intensive drying- and irrigation processes. A very important aspect by installing a moisture measurement sensor is a well conceived mounting position in the production plant. Every production plant has its own individual…
29-05-2015 |
32243
| product news |
Continue reading
Controlling of the Gypsum production at E.ON “MPP3”
based on a moisture measuring system from ACO
E.ON „MPP3“ coal fired power plant in Rotterdam-Maasvlakte The “MPP3” is the most modern and biggest hard coal fired power plant with the notable gross power rating of net 1070 MW and a net efficiency of over 46%. The “MPP3” wants to reduce the effects on the environment as much as possible. One point to reach an environmental friendly process is the optimisation of the exhaust-desulphurisation unit. The desulphurisation is made by a wet flue gas cleaning unit controlled by a moisture measurement. This flue gas desulphurisation (FGD) is far more effective than in other traditional coal fired power plants. Beyond the “MPP3” can reach a biomass-combustion up to 30%. Of course the district heating is used from the adjacent companies. General description of the process The desulphurisation is based on burnt lime (CaO) thereby the end product gypsum (calciumsulfad-dihydrat) arises. For the analysis of the produced gypsum there is an in-house…
12-03-2015 |
12848
| product news |
Continue reading
ACO moisture sensor in SFM1 compaction unit
ACO moisture measurement for biomass like wood chips, sawdust and wood shavings
Properties: Ideal material conditions for on-line moisture measurement Usable for various material Subsequently applicable in already existing plants Automatic cleaning of sensor surface Optional: turnkey control cabinet for triggering compaction unit The compaction unit SFM1_HACK is specially designed for the determination of residual moisture also of coarse material in the free fall. While the pneumatic cylinder moves the ”back panel” of the SFM1_HACK the falling down material can be compacted and pushed across the ACO moisture sensor in constant conditions. The measuring surface is cleaned automatically. The constant density and steady dumping height of the material enables great measuring results. The SFM1_HACK can be mounted by means of moldings or tubes directly at the dryer entrance but also it can be fixed to a wall (e.g. of a drop shaft). Flanges, screws and cover plate are included in delivery.
04-09-2008 |
22599
| press release |
Continue reading
ACO moisture sensor in PM1 sample taker
Application: ACO moisture measuring instruments for bulk solids (granulates)
Properties: Defined dumping height for ideal on-line moisture measurement The ACO sensor is integrated in the ”cup” of PN1 Long-lasting, pneumatic rotary drive Automatic cleaning of the sensor surface Optional: turnkey control cabinet for triggering sampler Versions: PN1 is available for all sensors of the ACO sensor family If required, the sampler can be manufactured as well integrated in e.g. a part of a drop shaft. The PN1 Sampler has to be mounted in a free fall situation, e.g. in a drop shaft. A part of the falling down bulk good is trapped in the cup. The bottom of this cup consists of the measuring surface of the ACO moisture measuring sensor. After enough material has been trapped, the residual moisture can be determined and finally that cup will be dumped. For cleaning the sensor an air nozzle has been integrated. The defined measuring height enables precise measuring results.
04-09-2008 |
23514
| press release |
Continue reading
❮
❯
PORTALS
✓
BulkSolids-Portal
Schuettgut-Portal
Recycling-Portal
Related
Bulkgids.nl
SIGN UP FOR OUR NEWSLETTER
Newsletter archive
Service and contact
About, Contact
Disclaimer
Privacy
Advertising
Control panel login
Follow us
Linked
Supplier sign in
✕
Choose your company:
Company not listed? Request a listing
Please leave your details and we'll create a listing.
Company name
Title
—
Mr
Ms
Contact person
E-mail address
Phone
‹ different company
Password
‹ different company
Forgot password?
Your name:
Send link
Didn't receive the e-mail? E-mail address out of date?