Supplier sign in
Home
STAY INFORMED
Subscribe to our monthly newsletter.
Your email address will never be disclosed to any third party.
Read our privacy notice.

       

Categories

Contribute
Transmitters
Select a category
Search

Companies

Penko Engineering B.V.
rotronic messgeräte gmbh
SCAIME S.A.S
Do you want to list your company here?  Add company

Posts

Density Transmitter DuoSeries LB 474
Density Transmitter DuoSeries LB 474
DuoSeries LB 474 is the new radiometric density system from Berthold based on real 2 wire technology, succeeding and compatibleour top-selling density measurement system LB 444. Like its predecessor model, the measuring system DuoSeries stands out by a particularly excellent performance with high accuracy and repeatability of level. Due to its outstanding performance the DuoSeries is the preferred choice when processes are demanding and 2-wire based control room technology is required. The DuoSeries density measuring system consists of a scintillation detector – CrystalSENS point detector – and a sophisticated transmitter unit for display and operation. The density transmitter is a state-of-the-art control unit with robust 3.5” TFT touch panel, powerful Dual Core CPU, up to 4 calibration curves, compensation of product temperature variations via PT100 connected to detector or analog current input and diverse operator interfaces. The calibration parameters can
17.03.2016  |  19236x  |  Product news  | 
The new signal conditioning instruments and isolating modules of the VEGATO Made from the same mould
The new signal conditioning instruments and isolating modules of the VEGATO
Made from the same mould VEGA has been developing the plics idea for more than 10 years now. The VEGATOR 100 series product family represents the latest step in this process: a standardized platform for signal conditioning instruments and barriers. In line with the plics philosophy, the housing platform has an integrated electronics and operating concept, delivering consistency and uniformity even among simple components such as signal conditioning instruments and isolating modules. Everything follows a modular concept: channel numbers and functions are clearly structured, making selection easier, along with standardized order codes, connectors, temperature ranges, operating instructions, and more, across the whole series. All devices of the VEGATOR 100 series have identical dimensions. Even in the case of the 2-channel models, VEGA maintains the standard width at 20 mm. This allows a higher installation density and number of channels to save valuable space in control cabinets. Careful
06.05.2014  |  17489x  |  Product news  | 
Oil monitor according to ISO 8573-5: 2010 Inline measurement of residual oil content in compressed air
Oil monitor according to ISO 8573-5: 2010
Inline measurement of residual oil content in compressed air According to ISO 8573-5: 2010 all hydrocarbons with 6 or more carbon atoms per molecule in compressed air need to be measured. The RCS Oil monitor is capable of measuring the residual oil with a minimum detection limit of 0,001mg/Nm3. The RCS Oil monitor is easy to install and optionally it is possible to expand the measurement range to CO2, CO, O2 and other possibilities up to ISO 8573-1. Because residual oil is an important measurement for the end quality of your produced product it is therefore the ideal monitor to install and monitor your compressed air quality. The complete set is delivered including a sample take-off point, a measurement system and a monitor system, providing you with a 4..20mA output or a RS485 digital link. The system only needs 230VAC, 50HZ power supply to start your measurement.
16.12.2013  |  5317x  |  Product news  | 
Zemic Europe proudly presents the new Top-Sensors line
Zemic Europe proudly presents the new Top-Sensors line
Zemic Europe proudly presents the new Top-Sensors line. We would like to introduce our T1 and T2 load cell transmitters. Features T1 Transmitters: • Weight transmitter and indicator for Omega/Din rail mounting. • EC Type-Approval Certificate DK 0199.367. • 0.2 µV/VSI, 10.000 divisions range. • 0.01 μV/VSI, 1.000.000 divisions range (for internal use). • Opto-isolated 16-bit analog output (4-20mA (max 300 ohm), 0-20mA, 0-10V, +/-10V, 0-5V, +/-5V (minimum 10 Kohm)). • Serial port RS485 for connection to PC/PLC by ASCII or ModBus RTU. • Optional protocols: Profibus DP, Ethernet/Modbus TCP, USB and Radio by appropriate converter. • 300 conversions/sec. (300 Hz) Features T2 Transmitters: •Weight transmitter and indicator for Omega/Din rail mounting • 0.2 μV/VSI, 10.000 divisions range. • 0.01 μV/VSI, 1.000.000 divisions range (for internal use). • Opto-isolated 16-bit analog output (4-20mA (max
20.09.2012  |  5933x  |  Product news  | 
FLUKE 772 and 773 Milliamp Clamp meters
FLUKE 772 and 773 Milliamp Clamp meters
EURO-INDEX introduces two new clamp meters which are capable of measuring 4 to 20 mA signal without breaking the loop. Numerous other calibrating functions are available on these instruments.
19.05.2009  |  6410x  |  Product news  | 
Do you have an item for this page?  Contribute
PORTALS
BulkSolids-Portal Schuettgut-Portal Recycling-Portal
Related
Bulkgids.nl
SIGN UP FOR OUR NEWSLETTER
Newsletter archive
Service and contact
ContactDisclaimerPrivacyAdvertising
FOLLOW US
Linked