Product news
15.04.2022  |  2151x
Share this item
Allow (tracking) cookies from YouTube and Vimeo to watch videos
ENVEA ProSens

Early recognition of dangerous dust concentration

Dust-laden exhaust air is produced during production at a confectionery manufacturer. A dangerous dust concentration shall be prevented by an early warning.

APPLICATION

A confectionery manufacuturer refines dairy products. The dust-laden exhaust air produced during the manufacturing process is cleaned in the extraction system by industrial filter systems. When the limit value is reached, a dangerous dust atmosphere is to be prevented by early warning.

A calibratable dust monitor shall continuously monitor the clean gas side according to the permitted dust concentration of max. 20 mg/m³.

PROCESS DATA

  • Customer: Confectionery manufacturer (Germany)
  • Product: Waffle dust
  • Permitted limit value: 20 mg/m³
  • Installation: Clean gas side of the exhaust duct of a dryer
  • Function: Continuous measurement of the dust content in the exhaust air

SOLUTION

In the application described, the ATEX type approved ProSens was used to measure the dust content. The ProSens can be calibrated and monitors clean gas sides downstream of filters continuously and reliably for permitted or customer-specified dust concentrations. It is used in metallic ducts where dust particles in the gas flow are to be detected. In this application, the sensor was installed in the exhaust air pipe downstream of a filter unit in order to detect a possible filter breakage and thus prevent the occurrence of a dangerous dust concentration. The pre-alarm is 7 mg/m³, and when it reaches the limit value of 20 mg/m³ the plant is shut down for safety reasons.

Thanks to the Dosed-Reference-Method developed by ENVEA, the ProSens can be calibrated quickly and safely in the customer‘s system. For this, ENVEA only requires a representative sample of the customer‘s filter dust, the specification of the desired limit value with regard to the dust concentration and some process data, such as the volume flow. With this information, a special dosing device can be set accordingly in advance, with which the technician then specifies the desired dust concentration to the sensor to be calibrated as a reference at the customer‘s site.

CUSTOMER BENEFITS

  • Reliable and continuous dust measurement in mg/m³
  • Safe compliance with permitted limit values (mg/m³)
  • Early prevention of dangerous dust conditions
  • Robust, durable, process-safe sensor technology (ProSens)
  • Simple, fast and verifiable calibration (Dosed-Reference-Method)

Company information

More items

Automatic salt dosing in food manufacture The measurement of the salt flow within the process allows a quick reaction to changes. A consitent product quality can be ensured.
Automatic salt dosing in food manufacture
The measurement of the salt flow within the process allows a quick reaction to changes. A consitent product quality can be ensured. Salt is blown from a silo, via a sieve and rotary valve, into the process. The salt flow is determined by a recipe setting and the speed of the rotary valve is linked to the depth of the product on a conveyor belt. Samples are taken and minor adjustments are made during the process. By installing an ENVEA SolidFlow in-line sensor, a trend of the salt flow has been determined and this is linked to the process control system to give an instantaneous reading. Process parameters have been set within the control system to alarm if the salt flow is either above or below tolerance. This enables the operator to react to changes within the process quicker, to maintain product consistency and quality. Process data * Industry: Food manufacture * Material/Quantity: Salt flow up to 200 kg/hr * Installation: (In-line) transfer line * Function: Flow measurement of ingredient addition What drove you to look for a solution? The original method was too slow to get a result.
11.04.2022  |  2013x  |  Product news  | 
PVC dust monitoring for early warning of hazardous dust concentrations With AirSafe 2 sensors ENVEA has realised continuous dust monitoring to give early warning of potentially hazardous dust concentrations in packaging areas.
PVC dust monitoring for early warning of hazardous dust concentrations
With AirSafe 2 sensors ENVEA has realised continuous dust monitoring to give early warning of potentially hazardous dust concentrations in packaging areas. At a PVC powder manufacturing site, robots are used in the packaging plant to fill 25 kg bags. The company’s ATEX guidelines state that there is an ATEX Zone 22 in the area of 5 metres around the plant. The ignitable mixture of PVC powder is 50 g/m3, which can happen if a bag does not withstand the pressure and breaks when being filled by a robot. However, by the time the system recognises this and internally switches off the filling, several kilos of material have often escaped into the ambient air, resulting in a potentially explosive atmosphere [> 50 g/m3]. Process data * Customer: Manufacturer of PVC powder * Material: PVC powder * Installation: In the packaging plant * Function: Dust monitoring to give early warning of potentially hazardous dust concentrations Solution In the application described, two AirSafe 2 sensors were used for continuous monitoring of the ambient air. In this case, a unit suitable for use in ATEX Zone 22 was used. The two
07.03.2022  |  2147x  |  Product description  |   | 
Avoidance of hazardous dust concentrations through monitoring Reliable and continous measurement of the dust concentration. Case study on dust measurement in exhaust air, so system can be shut down before a hazardous dust concentration is reached.
Avoidance of hazardous dust concentrations through monitoring
Reliable and continous measurement of the dust concentration. Case study on dust measurement in exhaust air, so system can be shut down before a hazardous dust concentration is reached. A well-known food manufacturer in Germany measures the dust value in mg/m3 in its exhaust air upstream of the fan in order to switch it off before a hazardous dust concentration is reached. The ignitable mixture of its dust is 30 g/m3. By calibrating to mg/m3, the desired switching point to turn off the system can be stored exactly. This way, the customer can be sure that the system is shut down before a hazardous dust concentration is reached. Process data: * Customer: Food manufacturer (Germany) * Material: Sugar dust * Installation: Clean gas side in front of the blower / Safety shutdown to protect the fan * Function: Reliable measurement of the dust content Solution: The ProSens sensor provided the solution to the application described which is used to continuously measure the concentration of the clean gas side after filters. The ProSens uses ElectroDynamic technology and through its robust and durable construction, provides a measurement solution to
09.02.2022  |  2101x  |  Product description  |   | 
Mass flow measurement for exact dosing for flue gas desulphurization Optimization of the lime hydrate-water dosing
Mass flow measurement for exact dosing for flue gas desulphurization
Optimization of the lime hydrate-water dosing In a waste incineration plant, hydrated lime is used in the dry sorption process for flue gas desulphurization (SO2 binding). The amount of hydrated lime is to be measured and water is to be added to bind the SO2. Since the throughput had not been measured so far and thus the incorrect amount of water added, the lime-water mixture in the collection tank clumped together. As a result, the tank had to be opened regularly to carry out the laborious process of removing the clumped material, resulting in downtimes. Process data - Customer: Incineration plant (Germany) - Material: Hydrated lime - Installation: Insulated free fall shaft downstream of a screw conveyor - Function: Optimization of the lime hydrate-water dosing Solution The SolidFlow 2.0 with extended sensor shaft (insulation) is used to measure and monitor the amount of hydrated lime actually pumped. The sensor continuously measures solids of up to 20 t/h in free fall or pneumatic conveying. In the